Revert: Remove 'group' attribute from macros

The 'group' attribute is not supported in all Klipper versions.
This caused: 'Option group is not valid in section gcode_macro'

Macros will appear under 'Uncategorized' in Mainsail/Fluidd
until Klipper adds official support for macro grouping.
This commit is contained in:
root 2026-03-13 11:24:10 +00:00
parent 651f4cb7eb
commit 3ac9e9fb1f
4 changed files with 0 additions and 26 deletions

View file

@ -11,7 +11,6 @@
# ----------------------------------------------------------------------------
[gcode_macro CALIBRATION_MENU]
description: Show calibration menu with all options
group: Calibration
gcode:
RESPOND MSG="=============================================="
RESPOND MSG=" NEPTUNE 4 PLUS CALIBRATION SUITE"
@ -34,7 +33,6 @@ gcode:
# ----------------------------------------------------------------------------
[gcode_macro CALIBRATE_Z_OFFSET]
description: Calibrate Z-offset using Cartographer touch
group: Calibration
gcode:
RESPOND MSG="Starting Z-Offset Calibration..."
RESPOND MSG=""
@ -64,7 +62,6 @@ gcode:
# ----------------------------------------------------------------------------
[gcode_macro CALIBRATE_INPUT_SHAPER]
description: Measure resonance frequencies with ADXL345
group: Calibration
gcode:
RESPOND MSG="Starting Input Shaper Calibration..."
RESPOND MSG=""
@ -87,7 +84,6 @@ gcode:
# ----------------------------------------------------------------------------
[gcode_macro CALIBRATE_PRESSURE_ADVANCE]
description: Calibrate Pressure Advance for optimal corners
group: Calibration
gcode:
{% set FILAMENT = params.FILAMENT|default("PLA")|upper %}
{% set START_PA = params.START|default(0.01)|float %}
@ -143,7 +139,6 @@ gcode:
# ----------------------------------------------------------------------------
[gcode_macro CALIBRATE_FLOW_RATE]
description: Calibrate flow rate for exact wall dimensions
group: Calibration
gcode:
{% set FILAMENT = params.FILAMENT|default("PLA")|upper %}
@ -195,7 +190,6 @@ gcode:
# ----------------------------------------------------------------------------
[gcode_macro CALIBRATE_TEMPERATURE]
description: Print temperature tower to find optimal temp
group: Calibration
gcode:
{% set FILAMENT = params.FILAMENT|default("PLA")|upper %}
{% set START_TEMP = params.START|default(195)|int %}
@ -240,7 +234,6 @@ gcode:
# ----------------------------------------------------------------------------
[gcode_macro CALIBRATE_RETRACTION]
description: Test retraction settings to minimize stringing
group: Calibration
gcode:
{% set FILAMENT = params.FILAMENT|default("PLA")|upper %}
{% set HOTEND = params.HOTEND|default("ORIGINAL")|upper %}
@ -303,7 +296,6 @@ gcode:
# ----------------------------------------------------------------------------
[gcode_macro CALIBRATE_BED_MESH]
description: Calibrate bed mesh with Cartographer
group: Calibration
gcode:
RESPOND MSG="Starting Bed Mesh Calibration..."
RESPOND MSG=""
@ -330,7 +322,6 @@ gcode:
# ----------------------------------------------------------------------------
[gcode_macro CALIBRATION_FULL]
description: Run complete calibration suite (takes ~2.5 hours)
group: Calibration
gcode:
RESPOND MSG="=============================================="
RESPOND MSG=" STARTING FULL CALIBRATION SUITE"
@ -390,7 +381,6 @@ gcode:
# ----------------------------------------------------------------------------
[gcode_macro CALIBRATION_QUICK]
description: Run quick calibration (Z-offset + PA + Bed Mesh, ~30 min)
group: Calibration
gcode:
RESPOND MSG="=============================================="
RESPOND MSG=" STARTING QUICK CALIBRATION"